CLiMET CI-99

– For Continuous Monitoring

Description

CI-99 t is an active air microbial sampler deployed in a fixed location, and generally used for monitoring isolators, RABS, and Biological Safety Cabinets (BSCs). It is the only model manufactured to meet or exceed all ISO 14698 standards and recommendations. Eliminate or mitigate deviation reports and investigations due to interval calibration out-of-tolerance conditions.

Models

CI-99 100 LPM Microbial Air Sampler

95009900x: CI-99 with Bottom Port Assembly
95009901x: CI-99 with Side Port Assembly

 

(x: Power Cord Type) 1=US; 2=UK; or 3=Euro

Sample Head

01210100: Aluminum Sample Head, 90 mm
01210103: Stainless Steel Sample Head, 90 mm

Features

Designed for automated microbial sampling for isolators
Sample a cubic meter in 10 minutes at 100 LPM flow rate, or segment a cubic over a user-specified period of time
Supports industry standard 90 mm petri dishes, or 60mm RODAC plates
The flow rate provides a critical element in both the velocity and impaction of the sample
Autoclavable Sample Head makes sanitation and disinfection easy
Fully compliant with VHP
Automatic Flow Control
Audible Flow Rate Alarm
The Biological and Physical Efficiency tested with excellent performance down to 1 μm
Up to 3 hours (possibly longer) of continuous sampling with a custom agar fill of 40mL in a 90mm petri dish is possible
Multifunctional adapter head allows remote monitoring in a biosafety cabinet or isolator, and sampling of high pressure gases
The only certified HEPA filtered exhaust
Connects to existing network infrastructure and variety of data logging or standard environmental monitoring systems including LIMS software
25 LPM and 1 CFM (28.3 LPM) flow rates are upon request

Why Should You Prefer Climet Products?

High Accuracy

“In Tolerance” ISO calibration rate of 98%

High Reliability

Over the past three years, 96% of Climet portable particle counters sold required no warranty repair service.

Drop and vibration tested

Ensuring end-users can expect up to a decade (and beyond) of reliable operation

Best OOT Value

Retrospective error investigation reduces the risk of cost loss to the lowest

Biological and Physical Efficiency

It has been tested with excellent performance up to 1 μm.

Autoclavable Sample Head

Makes sanitation and disinfection easy

Stainless Steel Enclosure

Minimize the risk of Bio-contamination

The only certified HEPA filtered exhaust
Resolution

Exceeds requirements of ISO of 15%. (Climet %4-10 typical)

50% Count Efficiency

Exceeds requirements of ISO of ±20%. (Climet <±10% typical)

100% Count Efficiency

±%10 per ISO

Connecting to Standard Environmental Monitoring Systems

Connects to existing network infrastructure and variety of data logging or standard environmental monitoring systems including LIMS software